Comparison of mild and standard pretreatment conditions for recommended positive control probe per tissue type

The following pages show positive control probe images with standard and mild pretreatment conditions. Optimal pretreatment condition is indicated for each tissue type.

2.2.1 Comparison of mild and standard pretreatment conditions for recommended positive control probe per tissue type

Positive control probe: Hs-PPIB

Tissue: Spleen

Pretreatment: Standard
SCORE 1-2+*
Pretreatment: Mild
SCORE 1-2+*

Observation: Loss of cell boundary using standard pretreatment.

Positive control probe: Hs-PPIB

Tissue: Lymph node

Pretreatment: Standard
SCORE 1-2+, 4+*
Pretreatment: Mild
SCORE 1-2+, 4+*

Observation: Loss of cell boundary using standard pretreatment. Signal: Mild ≥ Standard.

Positive control probe: Hs-PPIB

Tissue: Tonsil

Pretreatment: Standard
SCORE 2+, 3
Pretreatment: Mild
SCORE 2+, 4+*

Observation: Loss of cell boundary using standard pretreatment. Signal: Mild > Standard

Positive control probe: Hs-POLR2A**

Tissue: Retina

Pretreatment: Standard
SCORE 1-2+
Pretreatment: Mild
SCORE 2+

Observation: Loss of cell boundary using standard pretreatment. Signal: Mild ≥ Standard.

*A few cells have higher PPIB signals **Retina expresses low level of PPIB